Main

Pressure Switch Point Adjustment And Setting

This video provides simple instructions and tips on how to adjust and set mechanical and electronic pressure switch points, including switches with various electrical connections such as integral pin or cable, and DIN Form A. Our Social Media LinkedIn https://www.linkedin.com/company/noshok-inc- Facebook https://www.facebook.com/NOSHOKInc/ Instagram https://www.instagram.com/noshok_inc/ Twitter https://twitter.com/noshok Have a question or need help with an application? Live chat with us on our website: https://www.noshok.com Talk to our experts: 440-243-0888 Email: info@noshok.com NOSHOK, Inc. is a leading manufacturer of pressure, level, and temperature measurement instrumentation serving major industries around the world. Products include pressure gauges, pressure and temperature transmitters, transducers & indicators, pressure switches, needle valves, manifold valves, pressure snubbers, bimetal thermometers and diaphragm seals. These products meet and exceed the application requirements of OEMs and industrial users seeking exceptional quality, reliability and value. Industries served include fluid power, oil & gas, food & beverage, water/wastewater, industrial automation, power gen, transportation and marine. #constructionequipment #mechanicalswitch #lowcurrentswitch #hydrauliccrane #compactswitch #mobilehydraullic #hydraulics #pneumatics #pumps #compressors #tankmonitoring #leakdetection #watermanagement #NOSHOK #KINGGAGE

NOSHOK_Inc

12 days ago

Not all switches are as easy to adjust  as our 400 Series pressure switch which features an easily  adjustable adjusting knob, or the 800 Series which has a  user-friendly push button display. Be careful not to use your fingernails when  pushing the buttons as you may puncture the pads. Our 300, 200 and 100 Series switches have  the adjusting screw in the center of the head which uses a 2 mm Allen wrench. The adjusting screw can quickly be accessed by simply lifting the rubber  cover in the cent
er of the terminal pins. The 300 Series with integral pin or cable  requires the unit to be open to access the plastic adjusting screw. Be sure not to strip the screw head by overtightening. Or if you have the DIN EN 175301-803 Form A electrical connection you will first  need to remove the plastic head before accessing the adjusting screw. Insert your 2 mm Allen wrench into the adjusting screw and make clockwise  rotations to increase the switch point and counterclockwise to decrease the switch
point. Be careful as you make adjustments a little adjustment can result in a wide range change. After making the adjustment you will check the switch under pressure to determine how  far the switch point has moved. Continue to make small adjustments until the  desired switch point is reached. Please keep in mind that a mechanical switch not  only has a switch point but also a direction. That needs to be considered when  checking the switch point adjustments. Contact NOSHOK customer support or
your NOSHOK  Regional sales manager for additional assistance.

Comments